Quantification of aortic valvuloplasty catheter size using a metrology system based on brightfield microscopy

Download (175.44 kB)
Balloon aortic valvuloplasty (BAV) has been employed [1] as a simple and low-cost treatment method for patients with severe aortic stenosis, for symptom palliation in patients considered inoperable, for aortic valve replacement and to select the proper transcatheter heart valve (THV) size. During THV implantation choosing the correct balloon size is paramount for minimizing the risks of coronary occlusion, annular damage or THV embolization. Current methods for selecting the proper balloon dimensions are based on transesophageal echocardiography and computed tomography requiring trained staff for image interpretation, expensive equipment and high doses of patient radiation exposure. Alternative methods propose the use of BAV to determine the correct THV size before its implantation [2]. The strategy is based on determining the BAV aortic anulus using a sterile caliper. Any slight pressure to the balloon may compromise the measurement accuracy. In this paper, we present a non-contact metrology system for BAV measurement based on bright field microscopy (BFM). The balloons under test (MedTek-22 and TrueDilation-22) were clamped vertically, employing a tension spring to restrict movement and ensure perpendicularity to the microscope optical axis. The BFM is based on an Olympus PLN 4X WD~18.5mm, NA 0.1, a tube lens (f~180mm) and a FL3-U3- 13S2M-CS camera mounted on top of a custom-made linear stage having a coarse resolution of ~ 3.3µm. Balloon expansion was performed using a Boston scientific Encore 26 inflation device. The balloons are made up of an outer shell with an internal catheter tube (Ø~2mm). By focusing the microscope on the internal tube, then moving the linear stage to refocus on the balloon outer wall, the inner tube to outer wall dimension (see figure inset) can be accurately measured using the linear stage digital readout. The balloon was inflated up to six times recording the pressure and radius at each stage of inflation (twice the amount required for THV). Our non-contact method preserves the catheter sterile conditions and allows the accurate measurement of the BAV anulus showing: a) repeatability of the achieved balloon radius within all the inflation rounds, b) accurate measurements with a standard error of ±200 µm c) and a variation of 1.38 ±0.0387 mm from the manufacturer data. Knowing the exact balloon dimensions is crucial for avoiding the adverse consequences of THV oversizing. Our method may potentially improve the safety and efficacy of THV implantation.

History

Publication status

  • Published

File Version

  • Accepted version

Event name

Focus on Microscopy Conference 2019

Event location

London

Event type

conference

Event date

14 - 17th April 2019

Department affiliated with

  • Engineering and Design Publications

Research groups affiliated with

  • Sensor Technology Research Centre Publications

Notes

Scheduled in the Poster Session P2-D/26, Posters: Medical imaging, Brain imaging

Full text available

  • Yes

Peer reviewed?

  • Yes

Legacy Posted Date

2019-03-08

First Open Access (FOA) Date

2019-07-15

First Compliant Deposit (FCD) Date

2019-03-07

Usage metrics

    University of Sussex (Publications)

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC