Al0.52In0.48P 55Fe x-ray-photovoltaic battery
journal contribution
posted on 2023-06-09, 02:21 authored by Silvia Butera, Grammatiki LioliouGrammatiki Lioliou, A B Krysa, Anna BarnettAnna BarnettAn Al0.52In0.48P 55Fe radioisotope microbattery is demonstrated over the temperature range -20 °C to 160 °C. Al0.52In0.48P p+-i-n+ mesa structures were used to collect the photons from a 238 MBq 55Fe radioisotope x-ray source. The effects of temperature on the key microbattery parameters were studied. Increasing the temperature, the saturation current increased; whilst the open circuit voltage, the maximum power and the conversion efficiency decreased. An open circuit voltage of 0.97V and a conversion efficiency of 22% were measured in a single p+-i-n+ mesa structure at -20 °C. The highest total microbattery maximum output power using two mesa structures was 1.2 pW at -20 °C.
Funding
High Efficiency Betavoltaic Cells; G1455; STFC-SCIENCE AND TECHNOLOGY FACILITIES COUNCIL; ST/M002772/1
History
Publication status
- Published
File Version
- Published version
Journal
Journal of Physics D: Applied PhysicsISSN
0022-3727Publisher
IOP PublishingExternal DOI
Issue
35Volume
49Page range
1-7Article number